System Description
The Non-Rotating Canister (NRC) is a RTP canister system featuring a proprietary NR flange that permits rotation of the Beta flange relative to the canister body. The NRC is designed to interface with any industry standard RTP ports.
Advtanges and Applications
NRC Canister Advantages
The NRC Canister technology facilitates applications that are difficult to implement with standard RTP canister docking process requiring beta flange rotation relative to the alpha flange
- The shuttle and tray hardware permit the safe transfer of heavy or delicate parts into and out of isolator system.
- Material handling features and self supporting devices on the canister body that make its transport and docking safe for the operator.
- Customization of the canister body geometry and internal tray to the application.
NRC Canister Applications
- Production materials introduction: API, Stoppers
- Sterile part introduction during machine set up
- Sterile components introduction and removal during the production campaign
- Production Support Supplies: Micro supplies, cleaning supplies, tools.
- Product transfers into/out of the isolator chamber
Sterilization/Decontamination of the NRC Canister
The NRC canister must be either VHP decontaminated or steam sterilized prior to its use for aseptic transfers. Following are some notes regarding the two processes.
Steam Sterilization Process
- The NRC canister, with the beta door removed, is placed on a cart inside an autoclave. The autoclave must have an autoclave interface isolator. After the sterilization cycle, the NRC canister is transferred into the autoclave interface isolator where the operator installs the beta door via gloves. The sealed NRC canister is then transferred back through the autoclave and out to the manufacturing facility. It is now ready to use because its internal surfaces have been sterilized.
- Steam sterilization may also be accomplished by permitting steam to enter the canister via an absolute filter port located on the canister body itself.
VHP Gas Decontamination Process
- The NRC canister is decontaminated by docking it to the Alpha port of a transfer isolator, opening the RTP door and running a VHP decontamination cycle of the isolator itself.
- The NRC canister is placed inside a transfer isolator with the beta door removed and a VHP cycle run. At the end of the cycle, the operator installs the beta door onto the NRC via gloves and then the NRC is removed from the isolator
- The NRC canister is connected to a DECON unit manufactured by Dynamic Design Pharma, Inc. and the VHP cycle is run to decontaminate the canister. This process does not affect the aseptic manufacturing flow. This off-line process permits rapid decontamination of the canister using a standard VHP generator.
Documentation
Each system is shipped with a document which includes the following sections:
- Instruction Manual
- Operation Instructions
- Maintenance Instructions
- Recommended spare parts
- Assembly drawings
Validation Support
- Beta flange of each unit includes a Serial Number and its associated validation package. The validation package includes:
- Material certifications (aluminum, stainless, etc.)
- Surface treatment certification (passivation, anodize process, etc.)
- Leak test certification
Reference Documentation